• Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
  • Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
  • Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
  • Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
  • Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
  • Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber

Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber

Type: Pldd
Application: Orthopedic, Abdominal, Ent, Neurosurgery, Microsurgery, Burns
Material: Plastic
Feature: Reusable
Certification: CE, ISO13485
Group: Adult
Samples:
US$ 85/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Trading Company

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Hebei, China
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 19 foreign trading staff(s) and 10 staff(s) with over 6 years of overseas trading experience
Exhibition Experience
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (14)
  • Overview
  • Product Description
  • FAQ
Overview

Basic Info.

Model NO.
Fiber
Diameter
400um/600um/800um
Length
30cm
Interface
SMA905 International Standard
Transport Package
Aviation Box
Specification
45*48*53
Trademark
Triangel
Origin
China
Production Capacity
1000/Month

Product Description

Product Description

SMA905 international standard core diameter 400µm 600 µm 800 µm optical laser fiber cable, radial fiber and bare fiber, for surgery of EVLT ENT PLDD Dental Lipolysis Hemorrhoid Cutting Anal Fistula



Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
Products Description
 
SMA905 international standard Core diameter 400µm 600 µm 800 µm optical laser fiber cable, radial fiber and bare fiebr, for surgery of EVLT ENT PLDD Lipolysis Hemorrhoid the vena saphena magna and the vena saphena parva
Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
 
SILICA OPTIC FIBER FOR LASER INTERVENTIONAL THERAPY

This silica/quartz optical fibers are used with laser therapy instruments, mainly transmitting 400-1000nm semiconductor
laser,1604nm YAG laser, and 2100nm holmium laser.
 
The application scope of the laser therapy instruments includes: varicose veins treatment, laser cosmetic, laser cutting
operation, laser lithotripsy, disc herniation, etc.
Properties:
1. The fiber is provided with SMA905 standard connector;
2. The coupling efficiency of fiber is above 80% (λ=632.8nm);
3. The transmitting power is up to 200W/ cm2 (0.5m core diameter, continuous Nd: YAG laser);4. The fiber is interchangeable, safe
and reliable in operation;
5. Customer designs are available.
Applications:
Laser in operations, high power laser (e.g. Nd: YAG, Ho: YAG).
Urology (resection of prostate, opening of ureteral strictures, partial nephrectomy);
Gynaecology (septum dissection, adhesiolysis);
ENT (exision of tumors, tonsillectomy);
Pneumology (removal of multiple lung, metastases);
Orthopaedics (diskectomy, menisectomy, chondroplasty).
Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
 
360° RADIAL TIP FIBER produced by TRIANGEL RSD LIMITED applies energy faster and more accurately than any other fiber type in the endovenous market. FIBER (360°) used with SWING LASER ensures energy emission that guarantees homogenous photothermal destruction of the vein wall, allowing safe closure of the vein. By avoiding perforation of the vein wall and associated thermal irritation of the surrounding tissue, intra- and post-operative pain is minimized, as are echymosis and other side-effects.
RADIAL FIBER provides simple and safe control and positioning of the fiber thanks to the excellent ultrasound visibility of the distal end of the fiber. RADIAL FIBER is equipped with safety markings for optimal control of the pullback process.
Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber

 

Why Radial fiber?
When combined with the 980nm/1470 mm laser source, this laser fiber that emits at 360° affords the ideal endovenous thermal ablation. It is therefore possible to gently and evenly introduce the laser energy into the lumen of the vein and ensure the closure of the vein based on photothermal destruction (at temperatures between 100 and 120°C). Perforation of the vein wall (as in the case of the conventional bare tip fibre) and the associated thermal irritation of the surrounding tissue are prevented, thereby minimizing postoperative pain, ecchymosis, and other side effects. The TRIANGEL 360 Radial fiber (atraumatic fiber tip) is guided directly into the vein via a short introducer. Thanks to excellent visibility in ultrasound, the fiber tip can be optimally monitored and placed. Various publications have described the superiority of the Radial concept over the old generation of fibres.
Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber
When using a conventional end-face fiber (figure on the right), the laser energy leaves the fiber ahead and is scattered by a
cone. At the same time, an abrupt increase in temperature to a few hundred degrees occurs in the tip of the light guide, which contributes to the formation of carbon deposits at the tip of the fiber, to the ruptures of the vein to be treated, and as a
result to hematomas and pain in the postlaser period.
 
When using a radial light guide, the energy dissipates as a ring along the entire circumference of the vein (figure on the right). This is just an advantage that allows you to make the process of processing the veins unprecedentedly accurate and uniform. The effect of using such a fiber in comparison with the end - the ability to successfully handle the veins of any! diameter, absence of hematomas, pulling sensations in the postprocedural period. Terms of wearing compression knitwear after laser treatment using Radial technology are significantly reduced.
 

Medical Surgical Reusable SMA905 Connector 200um 400um 600um 800um Optical Radial Fiber/Bare Fiber/Conical Fiber

Construction of Fiber
This product consists of three parts. They are SMA905 standard connector, optical fiber, and protection tube. Optical fiber is
made of quartz glass. SMA905 standard connector is copper. And protective tube is made of silicone rubber.

Optical fiber transmission efficiency: when the total length of the optical fiber is ≤ 5m, the transmission efficiency of the
corresponding wavelength is not less than 80% when it is placed flat.

** Contact us if you need customization service.
 
FAQ
1. What is the Payment Terms?
Re: T/T (Wire Transfer), Western Union,Paypal, Money Gram,ect.
2. What is the delivery time?
Re: Five work days after receiving the full payments.
3. what is the delivery Method?
Re: By Express via DHL/ UPS/ Fedex/TNT,By air shipment, Sea shipment or any other appointed forwarder
4. What's packaging?
Re:Aluminum alloy case/carton case/wooden case.
5. Do you have after aftersales service?
Re: Yes. The products under warranty could be fixed or repaired based on different condition.
6. Do you have any other support?
Re:Yes, we could arrange the academic exchange activity and hospital surgery guidance if you need.
Any questions, pls feel free to contact us!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now