Gynecology surgery laser 980nm 1470nm diode laser for condyloma conization dysplasia myoma
Hysteroscopic Outpatient Laser Application
About one third of all women aged 30 and over is affected by myomas. The gentle and above all uterine preserving treatment of myomas is especially important for women who wish to have children.Myomas can be enucleated quickly and gently with Triangel Rsd Limited glass fibers in a variety of designs. The use of standard diagnostic hysteroscopes with small diameter allows direct treatment during diagnosis. The laser energy avoids contraction of the uterine muscles and can therefore be used without or under minimal local anesthesia. The extremely gentle intervention with
continuous irrigation with saline solution ensures a quick return to normal activities.
Endometriosis Laparoscopic Laser Application
Endometriosis is one of the main causes in women with abdominal pain and of unfulfilled desire to have children. In women with symptoms, the primary goal is the laparoscopic removal of endometriosis lesions. Laser energy, delivered via the glass fiber=optic, is used to precisely remove endometriosis lesions. Especially the resection of ovarian cysts is particularly gentle. First results of a study confirm the rapid recovery of the AMH value and the significant maintenance of the ovarian reserve*.
Advantages
Working in non-contact or contact with tactile feedback
Defined penetration depth without impact on surrounding tissue
Preservation of ovarian reserve and fertility
Minimally-invasive surgery
Laser surgery is also excellently suited for the treatment of condylomas or dysplasia in the areas of vulva, vagina and cervix.During conization, laser energy, delivered via the glass fiber optic, replaces the scalpel with the added benefit of excellent hemostasis. The defined penetration depth of the laser energy is less invasive, leading to fewer complications and a quick recovery of the patients.
Laser type |
Diode Laser Gallium-Aluminum-Arsenide GaAlAs |
Wavelength |
980nm+1470nm |
Power |
47w(for Cosmetic Gynaecology) |
Working Modes |
CW, Pulse and Single |
Aiming Beam |
Adjustable Red indicator light 650nm |
Fiber type |
600um radial fiber optional |
Fiber connector |
SMA-905 International standard interface, special quartz optical fiber laser transmission |
Pulse |
0.00s-1.00s |
Delay |
0.00s-1.00s |
Voltage |
100-240V, 50/60HZ |
Size |
48*40*30cm |
Weight |
5kg |
Dual waves laser 980nm 1470nm-Technology meets Anatomy
The 1470 nm/980 nm wavelengths ensure high absorption in water and hemoglobin. The thermal penetration depth is significantly lower than, for example, the thermal penetration depth with Nd: YAG lasers. These effects enable safe and precise laser applications to be performed near sensitive structures while providing thermal protection of the surrounding tissue.
Compared to the CO2 laser, these special wavelengths offer significantly better hemostasis and prevent major bleeding during surgery, even in hemorrhagic structures.
1. Non-ablative, stimulating collagen vaginal remodeling pain free precedure
2. Lunch break procedure at the Gynecology clinic(10-15min)
3. 360 scanning scope,easy to perform,and safe procedure
4. Efficient and long lasting results
5. No need for anesthetics with Non-invasive
6. Improves vaginal dryness and stress urinary in continence
7. Usually 3-5 sessions are recommended. No special pre-op preparation or post-op precautions are necessary.
Each involves the application of heat inside and around the vaginal opening to tighten skin and mucosa(moise intra vagina skin). Patients can immediately return to their normal everyday activities.